WALL SANDWICH PANEL

Secret Screwed wall sandwich panels are great construction materials for all types of buildings, including leisure, hospitals, industrial, retail, commercial, equipment storage, garages, boxes, cold and freeze stores houses and for thermal insulating packing for existing buildings.

ADVANTAGES OF PU SANDWICH PANELS:

  • Strong heat isolation
  • High level of fire resistance
  • High density
  • Weather resistance
  • " Design flexibility/simplicity
  • " Easy superficial cleaning
  • Construction lightness (building opportunity without the foundation in several cases)
  • Materials multiple usage ability
  • Stands out for economy of construction (does not need additional repair working)

TECHNICAL DETAILS

APPLICATIONS

For walls and ceilings

DIMENTIONS

Width: 1000 mm, Length: max 15 m

CORE MATERIAL

Polyurethane (PUR), Rockwool (RW), Expanded polystyrene (EPS)

POLYURETHANE THICKNESS

40-50-60-70-80-100-120-150 mm

UPPER SIDE COVER MATERIALS

Prepainted galvanized steel with protective layer

POLYURETHANE DENSITY

40 (+-2) kg/ m3

LOWER SIDE COVER MATERIALS

Polyurethane (PUR)

THICKNESS OF METAL SHEET

0.35- 0.60 mm

DESIGN

White grey. Other available

FLAMMABILITY CLASS

B2

SHOP NOW

SANDWICH PANEL CATALOGUE

CONSISTENCE

Sandwich panel metal surface consists of galvanized iron sheet and organic covering.
Organic covering is characterized with corrosion stability that contributes long service life of the material.

According to the corrosion type upper site metal cover of sandwich panel consists of: organic layer 25µm and galvanized layer 20 µm that can be raised up to 200 µm upon requirements

PREPAINTED GALVANIZED SHEET IRON

Panex uses prepainted galvanized sheet iron in coils that is produced according to ECCA
(The European Coil Coating Association) standards.
Sheet iron mark DX51D + Z EN 10327
Thickness tolerance (0,35 mm < iron thickness 0,6 mm) +0.05 mm EN 10143
Tensile Strength 500 (max.) EN 10327
Elongation,% 22 (min.) EN 10327
Paint amount 100-275 gr/m EN 10327
Paint typet Polyester Polyester, PVdf, Plastisol, PVC, Polyurethane etc EN 10327

POLYURETHANE SOLID FOAM

In sandwich panels we use polyurethane foam with the best heat isolation performance. Polyurethane foam is waterproof material and has antibacterial characteristics.
Density 40 (+2) kg/m³ EN 1602
Thermal conductivity ratio 0.022 – 0.024 W/mk EN 13165
Closed cell percentage 95% EN 14509
Steam diffusion 30-100 EN 12086
Stability in sizes Level DS(TH)11 EN 13165
Stability to pressure (Mpa) (10) min. 0,095 EN826
Water absorption (vol. %) 2% (168 hours) Producer method
Usage tem. margins (° C) -200/+110 (° C)

HEAT ISOLATION

To achieve the desired results in case of low thermal insulation materials it is necessary to
increase material thickness. While in case of polyurethane foam the minimum thickness of
material is remained.

According to thermal insulation values, multifunctional usage and exploitation durability, today polyurethane foam is the optimal solution.

THERMAL CONDUCTIVITY VALUE

Panel thickness Thermal conductivity U(W/m2) Thermal conductivity U (KCAL/m2)
40 mm 0.4973 0.4276
45 mm 0.4468 0.3842
50 mm 0.4056 0.3488
60 mm 0.3424 0.2944
80 mm 0.2611 0.2245
100 mm 0.2110 0.1814
120 mm 0.1771 0.1522
150 mm 0.1426 0.1226

MECHANICAL STABILITY

Lifting capacity is an important issue while sandwich panel selection for the specific building. Factors such as own weight, wind load, snow load and temperature can effect on building as together as separately.

Sandwich panel consistent metal sheets and fillers between these two sheets have low lifting capacity but composition which is made by these materials is a new system and its lifting capacity is compatibly improved.

MECHANICAL STABILITY

Lifting capacity is an important issue while sandwich panel selection for the specific building. Factors such as own weight, wind load, snow load and temperature can effect on building as together as separately.

Sandwich panel consistent metal sheets and fillers between these two sheets have low lifting capacity but composition which is made by these materials is a new system and its lifting capacity is compatibly improved.

FIRE RESISTANCE RATING

PUR material is effective while fire. Polyurethane foam with its chemical coponents can reduce and prevent fire from spreading that increase product efficiency.

Panex polyurethane panels are classified with B2 fire resistance rate (based on TS EN 14509 standarts)

Stability in sizes while heating

+100 C° PUR

Inflammation temperature

+285 C° PUR

FIRE RESISTANCE RATING

PUR material is effective while fire. Polyurethane foam with its chemical coponents can reduce and prevent fire from spreading that increase product efficiency.

Panex polyurethane panels are classified with B2 fire resistance rate (based on TS EN 14509 standarts)

Stability in sizes while heating

+100 C° PUR

Inflammation temperature

+285 C° PUR

SOUND ISOLATION

SOUND TRANSFER LOST ACCORDING TO FREQUENCY

PUR Frequency (Hertz)
kal 125 160 200 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 6300 8000
50 mm 7.3 9.3 11.7 11.4 12.3 13.3 14.41 14.7 15.9 15.3 11.5 11.8 23.4 29.2 32.4 29.8 32.5 36.9
60 mm 8.1 22.1 14.2 13 13.9 13.8 14.6 15.3 16 15.3 13 18.3 24.2 29.2 32.5 29.8 32.5 36.9

SOUND ABSORPTION RATIO ACCORDING TO CHANGE FREQUENCY

PUR Frequency (Hertz)
kal 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000
50 mm 0.08 0.11 0.22 0.2 0.05 0.59 0.09 0.11 0.04 0.07 0.18 0.07
60 mm 0.14 0.21 0.25 0.25 0.06 0.69 0.12 0.12 0.22 0.08 0.2 0.11

If You Need Any Industrial Solution ... We Are Available For You

Contact Us